Power and processing in two rack units.
Every extra box in the rack is one more thing to lift, wire and set up. The NX6000D delivers 2 x 3000 W into 4 Ω and weighs 6.0 kg. Crossover, EQ, delay and limiters sit inside the same two rack units.
Tune the speakers at the amplifier
The digital crossover offers 3 filter types with slopes up to 48 dB/octave. Each channel adds 8-band parametric EQ and a 2-band dynamic equaliser. Delay a channel by 0 to 300 ms, or flip its phase, to correct cancellation in your system.

Bi-amp from one chassis
Select BIAMP1 on the Amp Mode screen. Set a high-pass filter on channel A and a low-pass filter on channel B. Each band then goes to its own cabinet, and a subwoofer typically takes the lows.

Settings that stay put
The limiters take your own threshold, release and hold settings. Store presets, then lock the panel with a password. Over USB, DSP control software from behringer.com controls the parameters from a computer.